Спецификации
Optical System | CFI60 infinity |
---|---|
Illumination | 6V-30W halogen lamp; 6V-30W transformer built-in; ND8, ND4 filters built-in |
Focusing |
Coaxial coarse/fine focus knob; Focus stroke: 30mm; Coarse: 9.33mm per rotation; Fine: 0.1mm; Minimum reading: in 1µm increments |
Eyepiece | 10x (F.O.V. 22mm) |
Eyepiece tube | P-TT3 Trinocular Tube for polarizing microscopy; P-TB2 Binocular Tube for polarizing microscopy |
Intermediate tube | Built-in focusable Bertrand lens removable from optical path; Conoscopic/Orthoscopic observations switchable; Analyzer built-in; Plate/compensator slot |
Analyzer | 360° rotary dial; Minimum reading angle 0.1° |
Nosepiece | Centering quintuple nosepiece (detachable); DIN slot |
Stage |
Ball bearing rotary stage; Rotatable 360° horizontally; can be fixed at a specific position; Graduated 360° (in 1° increments); Rotation clamp equipped; Attachable mechanical stage: 35 x 25 mm travel; vernier 0.1mm |
Condenser | Dedicated strain-free swing-out type; P Achromat N.A. 0.9 |
Polalizer | No scale markings |
Objectives |
CFI P Achromat 4x, 10x, 20x, 40x, 100x CFI TU Plan Fluor Epi P 5x, 10x, 20x, 50x,100x |
Episcopic illuminator |
LV-UEPI-N Universal Epi-illuminator Requires an external power supply |
Compensators | P-CL Standard 1/4 λ & tint plate, quartz wedge or Senarmont compensator can be inserted into intermediate tube slot |
Power consumption | 0.8A/38 W |
Weight | Approx. 14kg (standard binocular set) |
Характеристики
Eclipse Ci Polarizing Polarizing Microscope, Eclipse Ci Polarizing, NIKON INSTRUMENTS, ПОЛЯРИЗАЦИОННЫЕ МИКРОСКОПЫ, (АРТ 575) | |
---|---|
Модель: | Eclipse Ci Polarizing |
Производитель: | NIKON INSTRUMENTS |
Характеристики | |
Optical System | CFI60 infinity |
Focusing | Coaxial coarse/fine focus knob; Focus stroke: 30mm;Coarse: 9.33mm per rotation; Fine: 0.1mm;Minimum reading: in 1µm increments |
Nosepiece | Centering quintuple nosepiece (detachable); DIN slot |
Illumination | 6V-30W halogen lamp; 6V-30W transformer built-in; ND8, ND4 filters built-in |
Objectives | CFI P Achromat 4x, 10x, 20x, 40x, 100xCFI TU Plan Fluor Epi P 5x, 10x, 20x, 50x,100x |
Eyepiece | 10x (F.O.V. 22mm) |
Eyepiece tube | P-TT3 Trinocular Tube for polarizing microscopy; P-TB2 Binocular Tube for polarizing microscopy |
Intermediate tube | Built-in focusable Bertrand lens removable from optical path; Conoscopic/Orthoscopic observations switchable; Analyzer built-in; Plate/compensator slot |
Analyzer | 360° rotary dial; Minimum reading angle 0.1° |
Stage | Ball bearing rotary stage; Rotatable 360° horizontally;can be fixed at a specific position; Graduated 360° (in 1° increments);Rotation clamp equipped;Attachable mechanical stage: 35 x 25 mm travel; vernier 0.1mm |
Condenser | Dedicated strain-free swing-out type; P Achromat N.A. 0.9 |
Polalizer | No scale markings |
Episcopic illuminator | LV-UEPI-N Universal Epi-illuminatorRequires an external power supply |
Compensators | P-CL Standard 1/4 λ & tint plate, quartz wedge or Senarmont compensator can be inserted into intermediate tube slot |
Power consumption | 0.8A/38 W |
Weight | Approx. 14kg (standard binocular set) |